Direct answer: On 12 November 2026 the US Consumer Product Safety Commission announced that Allstar is recalling Sharper Image tabletop and infinity fire pits after four reports of ignited fuel escaping from the unit during use, producing four injuries including third and fourth degree burns. These are outdoor appliances used on tables, decks and balconies, where no smoke alarm can see them.
Key points
- Recall 27082, announced 12 November 2026, covers Sharper Image tabletop fire pits and tabletop infinity fire pits marked with a “77” logo and KS-CY or KS-FC lot codes.
- Four reports describe burning fuel escaping the burn chamber while in use, with four injuries and third to fourth degree burns.
- Both variants burn liquid fuel in an open chamber: one has a concrete body with a snuffing lid, the other a steel base with tempered glass panels.
- Detection is an indoor problem. A balcony fire reaches a detector through the door it passes, not through the ceiling above it.
Why this matters
Open-chamber ethanol and gel fire pits have moved from restaurant terraces onto residential balconies, and the failure mode here is the dangerous one: fuel that leaves the burner while it is burning. A pool of burning fuel crossing a table reaches skin before a person can move, and the burns are deep because the flame stays close and keeps being fed. The detection problem is structural. Residential smoke alarms are installed to protect the interior escape route, so a balcony fire is outside their designed coverage; by the time smoke rolls through the door, the fire has already taken hold against a railing, a plastic chair or an external cladding system. For landlords the recall adds a duty: establish whether any recalled unit is in use in a rented flat or on a shared terrace, and remove it.
Technical detail and compliance
The device is a liquid-fuel pool burner with no automatic shut-off, no flame supervision and no fuel-level interlock, which is why the remedy is removal rather than repair. Ethanol and gel flames are hard to see in daylight and near-invisible in bright sun, so a user refilling or moving a lit unit gets no visual cue that fuel has spilled. CPSC's remedy is a refund or replacement through the firm, and the operating instruction is to stop using the unit and never refill it while lit or still warm. On the detection side, NFPA 72 covers the dwelling interior: smoke alarms on each level, inside and outside sleeping rooms, interconnected, with devices listed to UL 217. Where a balcony door opens into a bedroom, the alarm required outside that sleeping room is also the device closest to the balcony, so its position relative to the door matters more than its position relative to the bed.
What US property managers should do now
Multifamily operators face three overlapping rules: the recall itself, lease terms prohibiting open-flame appliances on balconies, and local fire codes restricting open flame on combustible balconies and decks. The efficient response is to add open-flame devices to the pre-season checklist and issue a notice naming the recalled models rather than a generic prohibition. For buildings with detection upgrades in progress, the same walk is the moment to confirm that the alarm serving the room with the balcony door is interconnected and within its service life, since that device is the only automatic warning the building will get.
Procurement and implementation advice
When specifying detection for units with balconies, treat the room adjacent to the door as a priority zone: a photoelectric smoke alarm inside the room, interconnected with the dwelling, positioned between the door and the sleeping area rather than on the far wall. Do not rely on a heat alarm here, because a balcony fire produces smoke long before it produces a ceiling temperature rise indoors. For outdoor cooking and heating appliances, require automatic shut-off and flame supervision in the purchase specification, and require fuel containers to carry a clear prohibition on refilling while lit. Wanlin's interconnected residential devices and their documentation are listed in the product centre.
Frequently asked questions
Does this recall apply to units sold outside the United States?
The CPSC notice covers the US market, but the models are sold internationally under the same brand family. Importers should check lot codes KS-CY and KS-FC against their own stock rather than assuming the recall is geographically contained, and verify any unit with a concrete body and snuffing lid or a steel base with glass panels.
Will a smoke alarm detect a balcony fire early enough?
Only once smoke enters the room. A balcony fire is outside the detector's designed volume, and an alarm on the far bedroom wall may not respond until the smoke layer has spread. Placing the alarm between the balcony door and the bed, and keeping that door closed at night, gives the earliest warning.
Should a fire pit be replaced with gas or electric?
From a fire-safety standpoint, a sealed gas unit with flame supervision or an electric unit removes the fuel-handling hazard entirely. If a liquid-fuel unit is kept, the minimum controls are a stable non-combustible base, no refilling while lit, and at least one metre of clearance from railings, plants and furniture.
Reviewed by the Wanlin Fire technical team. Source: CPSC recall 27082, 12 November 2026; NFPA 72 and UL 217 requirements.