WANLIN-340 NB-IoT Standalone Heat Alarm

Wanlin Fire | Smoke Alarm & Fire Safety Equipment Manufacturer · Product evidence and selection information

WANLIN-340 NB-IoT Standalone Heat Alarm

WANLIN-340 standalone heat alarm with DC 3 V battery power, local audible and visual warning, NB-IoT reporting and low-battery indication.

  • Release Date:2026-10-23
  • Product Description: WANLIN-340 standalone heat alarm with DC 3 V battery power, local audible and visual warning, NB-IoT reporting and low-battery indication.
  • Consult Now

Selection and application evidence

Use the published product information to shortlist a model, then verify the current datasheet, protocol, power supply, certificate scope and destination requirements before specifying or purchasing.

WANLIN-340 is a standalone heat alarm with local sound and light warning plus NB-IoT event reporting. It is intended for environments where a smoke alarm may be unsuitable, including dusty areas, kitchens, boiler rooms and locations where smoke or steam can normally remain in the air. The detector continuously evaluates temperature and initiates its alarm when the configured threshold is reached.

WANLIN-340 at a glance

Heat detection
MCU-based temperature evaluation with automatic recovery after the ambient temperature falls.
Local warning
Red indicator and built-in sounder provide audible and visual alarm notification.
Remote reporting
The documented NB-IoT module sends alarm data to the associated IoT service.

Technical specifications

ModelWANLIN-340CommunicationNB-IoT
Rated voltageDC 3 VBattery capacity2400 mAh
Standby current≤6 µAAlarm current≤100 mA
Sound pressure level45–75 dB at 3 m directly in frontOutputAudible and visual alarm
Operating temperature0 °C to +55 °CRelative humidity≤95% RH at 40 °C ±2 °C
WeightApproximately 140 g including batteryPublished standardGB 30122-2013

Application guidance

The manual describes installation in factories, homes, shops, equipment rooms, warehouses and other locations where smoke detection may be unsuitable. It lists high-humidity environments, dusty areas, smoking rooms, kitchens, boiler rooms, generator rooms and drying workshops as example applications. Final detector selection and spacing must follow the project fire strategy and applicable local rules.

Alarm threshold: The supplied manual refers to a preset temperature threshold but does not state its numeric value. Confirm the current threshold, classification and project acceptance requirements before ordering.

Installation and testing

1. Confirm the location
The manual describes ceiling mounting and a nominal 30 m² protection area where the space height is below 8 m, subject to the project design standard.
2. Fix the base
Drill two mounting holes 75 mm apart and secure the base with suitable expansion plugs and screws.
3. Connect the battery
Connect the 3 V lithium battery with the correct polarity, then attach and lock the detector to its base.
4. Run a self-test
Use the test control to confirm the red indicator and audible signal before handover and during scheduled maintenance.

Status and maintenance

  • Normal status: the indicator flashes approximately once every 50 seconds.
  • Low battery: below 2.7 V, the indicator and a single chirp occur approximately every 50 seconds.
  • Alarm status: the red indicator illuminates and the sounder operates when the preset threshold is reached.
  • Silence: pressing the control during alarm temporarily silences the sounder for approximately 80 seconds; the alarm resumes if the condition remains.
  • Do not dismantle or repair the detector without qualified support.

Product document

Evidence boundary: This page reflects the supplied product manual. No CE, FCC, UL or other third-party certification is claimed because no certification document was supplied for this model.

Confirm the WANLIN-340 configuration

Send the destination country, installation environment, ceiling height, required alarm threshold, NB-IoT network conditions, quantity and approval requirements.

Source basis: WANLIN-340 standalone heat alarm manual, version 1.0, reviewed 23 October 2026.