10-Year Battery Smoke Detector, Long-Life Battery Smoke Alarm, Sealed Battery Photoelectric Smoke Detector, 10-Year Lithium Smoke Sensor, Maintenance-Free Smoke Tester
Hotline
Customer Service Hotline:

+8613261677119

Product Center

WANLIN-307 Connected Smoke Alarm for Germany

Wanlin Fire | Smoke Alarm & Fire Safety Equipment Manufacturer · Product evidence and selection information

WANLIN-307 Connected Smoke Alarm for Germany

WANLIN-307 photoelectric smoke alarm for Germany. Compare standalone, 433 MHz, LoRa, NB-IoT and 4G variants, evidence requirements and OEM options.

  • Release Date:2026-10-14
  • Product Description: WANLIN-307 photoelectric smoke alarm for Germany. Compare standalone, 433 MHz, LoRa, NB-IoT and 4G variants, evidence requirements and OEM options.
  • Consult Now

Downloadable product evidence

WANLIN-307 Certification and Test Documents

The documents below identify WANLIN-307 within the model family stated in each PDF. Review them together with the current quotation, product label, manual and exact ordered SKU.

CE certificate · PDF

EN 14604 CE Certificate

Certificate: JAT26092402656SC-1

Models listed: WANLIN-307, WANLIN-303, WANLIN-304 and WANLIN-309

Open CE certificate (PDF)
Test report · PDF

EN 14604 Test Report

Report: JAT26092402656SR-1

Laboratory test evidence for the submitted WANLIN-307 sample against EN 14604:2005+AC:2008.

Open EN 14604 test report (PDF)
FCC SDoC · PDF

FCC Part 15B Compliance Statement

Statement: JAT26092402656FC-1

Supplier's Declaration of Conformity evidence referencing FCC Part 15 Subpart B and ANSI C63.4.

Open FCC SDoC statement (PDF)
Test report · PDF

FCC Part 15B Test Report

Report: JAT26092402656FR-1

Conducted and radiated emissions test results for the submitted WANLIN-307 sample.

Open FCC Part 15B test report (PDF)

Scope note: These files document only the products and model family stated in each PDF. They do not by themselves establish that every 4G radio module, frequency band, SIM arrangement or destination-market configuration is covered. Confirm the exact ordered SKU and current document revision before approval.

Selection and application evidence

Use the published product information to shortlist a model, then verify the current datasheet, protocol, power supply, certificate scope and destination requirements before specifying or purchasing.

Direct answer for distributors, integrators and project buyers

What is the WANLIN-307?

WANLIN-307 is a photoelectric smoke alarm family available in standalone, 433 MHz interconnect, LoRa, NB-IoT and 4G configurations. The correct version depends on whether the project needs only a local audible warning, alarm propagation between rooms, or remote event reporting to a monitoring platform.

Selection boundary: certification scope, permitted radio band, battery configuration, cloud protocol and labeling must be confirmed against the exact ordered SKU and current project documents. A feature shown for one WANLIN-307 variant must not be assumed to apply to every variant.

Buyer Decision Snapshot

Choose by outcome

Local warning, multi-room interconnection and remote monitoring are different requirements. Select the communication architecture before comparing price.

Verify by SKU

Ask for the model suffix, power arrangement, frequency, protocol, certification file and manual that match the units being quoted.

Approve by evidence

Final approval should use the current datasheet, applicable certificate, sample test, label artwork and written project specification.

WANLIN-307 Variant Selector

Scroll horizontally on small screens to compare all columns.

WANLIN-307 communication variants and pre-order verification points
VariantCommunication roleTypical project needConfirm before ordering
StandaloneLocal audible alarmIndividual rooms and simple residential replacementPower source, service-life claim, sound output and applicable approval
433 MHz interconnectLocal device-to-device alarm propagationMulti-room dwellings and small propertiesPermitted market frequency, group capacity and indoor range
LoRaLong-range low-power reporting through a compatible gatewayCampuses, warehouses and distributed buildingsFrequency plan, gateway compatibility, payload and supervision interval
NB-IoTOperator-network event reportingRemote properties requiring managed cellular connectivityCarrier coverage, SIM/eSIM arrangement, data plan and platform endpoint
4GDirect cellular event reportingSites needing independent wide-area communicationLTE band support, peak power demand, reporting interval and recurring connectivity cost

Where the Product Fits — and Where It Does Not

Potentially suitable

  • Residential and rental-property smoke warning
  • Hotels, student housing and managed accommodation
  • Warehouses and remote rooms requiring event reporting
  • OEM or private-label distribution programmes
  • Retrofit projects where new signal wiring is impractical

Requires a different design or further approval

  • Applications requiring a complete addressable fire alarm control system
  • Hazardous areas or outdoor exposure without an approved enclosure
  • Projects where the selected radio band is not permitted locally
  • Life-safety tenders requiring a certificate not held by the quoted SKU
  • Any installation where local rules require a licensed designer or installer

Germany Market and Project Checklist

  1. Define the device class. Confirm whether the requirement is a self-contained smoke alarm or a detector forming part of a fire alarm system.
  2. Lock the exact variant. Record standalone, 433 MHz, LoRa, NB-IoT or 4G on the quotation and sample request.
  3. Verify market documentation. Review the applicable product standard, declaration, test evidence and German-language user information for the exact SKU.
  4. Confirm radio and connectivity. Verify the frequency, network operator, gateway and platform interface before shipment.
  5. Test a sample in the intended workflow. Check alarm behavior, notification path, battery reporting and platform acknowledgement rather than relying only on a brochure.
  6. Approve production evidence. Freeze the label, manual, packaging, serial-number format and inspection plan before mass production.

This page describes a configurable product family and is not a substitute for a project fire strategy, local approval or the documents supplied with the final SKU.

Evidence Pack to Request

IdentityExact model and variant suffix, product label and serial-number format
TechnicalCurrent datasheet, power specification, radio parameters and protocol description
ComplianceCertificate and test report whose model scope matches the ordered SKU
IntegrationGateway compatibility, event fields, API or MQTT definition where applicable
ProductionApproved sample, inspection criteria, packaging and manual revision
CommercialMOQ, lead time, warranty terms, Incoterm and after-sales process in writing

OEM/ODM Project Workflow

1. Requirement briefMarket, application, communication method, quantity and required documents.
2. Variant matchWanlin identifies the appropriate WANLIN-307 configuration and exclusions.
3. Evidence reviewBuyer checks the model-specific datasheet, certification scope and sample.
4. Pilot verificationAlarm, interconnection or remote reporting is tested in the intended workflow.
5. Production releaseArtwork, manuals, labels, inspection plan and delivery terms are frozen.

WANLIN-307 Frequently Asked Questions

Is WANLIN-307 one product or a family of variants?

It is presented as a product family. Standalone, 433 MHz, LoRa, NB-IoT and 4G configurations serve different communication requirements. The quotation and evidence pack should identify the exact variant.

Which WANLIN-307 version is suitable for remote monitoring?

LoRa, NB-IoT and 4G versions can support remote reporting when paired with the required gateway, network service or platform. Compatibility and the event interface must be confirmed for the selected SKU.

Can the 433 MHz version be supplied for Germany?

Do not select a radio variant by name alone. The permitted frequency, power and conformity route must be checked for the destination market and the exact device configuration before ordering.

Does every WANLIN-307 variant have the same certification?

No assumption should be made across variants. Radio, battery and connectivity changes can alter the applicable evidence. Request documents listing the exact model or variant being purchased.

What should a German distributor request before placing a bulk order?

Request the exact SKU datasheet, applicable certificates and reports, German-language instructions, label artwork, sample test plan, warranty terms and written confirmation of the radio configuration.

Is OEM or private-label supply available?

OEM and ODM cooperation can include branding, labels, packaging, manuals and project-specific configuration, subject to quantity, certification scope and written approval of the final specification.

How should buyers compare the standalone and connected versions?

Compare the required outcome first: local warning, room-to-room propagation or remote reporting. Then compare power, supervision, infrastructure, recurring connectivity cost and model-specific compliance evidence.

Information Provenance and Update Policy

Responsible entity: Wanlin Fire Equipment, Shenzhen, China. Audience: international distributors, integrators, OEM buyers and project teams. Verification rule: product claims are subordinate to the current model-specific datasheet, certificate, test report, approved sample and written sales specification.

Last structured review: 16 October 2026. Contact wanlinfirecontrol@163.com to request the current evidence pack or report an inconsistency.